If your furnace is turning on and off in short succession—and for only a few minutes at a time—this behavior is called short-cycling.

What Causes Short-Cycling?

  • Clogged Air Filter. …
  • Blocked Air Vents. …
  • Poorly Located Thermostat. …
  • Damaged Flame Sensor. …
  • Cracked Heat Exchanger.

Why does my furnace keep turning on every few minutes?

1 – Low airflow



There are several indirect issues that cause low airflow. Dirty Air Filters. If you don’t change your air filters often enough, the filters will become dirty and clogged, which means the heat exchanger retains heat and eventually causes it to overheat.

Why is my new furnace short cycling?





A dirty air filter is the most common cause of short-cycling. If your air filter is clogged with dirt, it won’t allow proper air flow to the heat exchanger. That can cause the furnace to overheat and forces the high limit switch to ride to the rescue by shutting the furnace off.

Why does my furnace cycle every 5 minutes?

Blocked Exhaust Vent



This is another cause of a furnace overheating and short cycling. Short cycle time: 1-5 minutes. This issue can be dangerous too, since deadly carbon monoxide is dispersed through the vent. If it is blocked, the gas won’t escape, and it can leak out of the furnace and into your home.

How often should a forced air furnace cycle?

three to eight times per hour

While it should cycle throughout the day, clicking on too frequently may indicate a problem. Homeowners often find themselves wondering, “How often should my furnace cycle?” The answer lies in a gray area. On average, furnaces should kick on and turn off anywhere from three to eight times per hour.

How do I stop my furnace from short cycling?





Quote from the video:
Quote from Youtube video: So to fix this issue shut off your thermostat. And open up the furnace. And then replace the batteries on the thermostat.

How often should a furnace cycle on and off?

3-8 times per hour

On average, furnaces should kick on and off anywhere from 3-8 times per hour. However, if your furnace does so more frequently, don’t assume it’s short cycling just yet.

Why does my furnace run every 10 minutes?

It cycles off because an inner safety is getting overheated from inadequate airflow. Either get a smaller furnace or enlarge the duct system to move the amount of air needed by the furnace.

Why does my furnace blower turn on and off constantly?



If your blower is constantly turning on/off when the furnace isn’t heating… …you most likely have a bad fan limit switch. Your furnace fan limit switch is basically a control system that determines when the furnace blower assembly should turn on and off.

Why does my furnace turn on so often?

When a furnace keeps turning on and off, it is usually due to short cycling. This is the term used to describe problems originating from within the heating system. If short cycling is not promptly diagnosed and corrected, it could cause permanent damage to your heating unit and higher utility bills.

Why does my heater turn off after a few minutes?

If your furnace turns off after a few minutes, there is a good chance it is caused by a faulty or dirty flame sensor. This vital component is designed to keep an eye on the gas burner. When it cannot sense that burner, the furnace runs then shuts off and starts again. This could be a relatively easy fix.

How do you fix a short cycling boiler?



Adding thermal mass to the heating system will decrease the burner short cycling and this can be done by adding water volume to the system. A relatively easy way to add thermal mass is adding a “Buffer Tank”.

What is a short cycle HVAC?

Short cycling is an HVAC term used to define a situation where a furnace or air conditioner turns on and off too frequently. The term “short-cycle” describes the period of time that your HVAC equipment is actually running, and the shorter this cycle, the harder your system needs to work.

Why does my furnace turn off after 15 minutes?

If your air filter is too dirty, it will restrict airflow. Your furnace will then shut off prematurely to avoid overheating. We recommend replacing flat filters once a month, and pleated filters every three months. It’s easy to stay on top of changing your filter by adding a Filter Reminder on your thermostat.

How do I stop short cycling?

How To Stop and Prevent Short-Cycling

  1. Check your air filter. Believe it or not, a clogged air filter can cause a wide variety of air conditioning issues. …
  2. Check your thermostat placement. …
  3. Check your air conditioner’s refrigerant levels. …
  4. Replace the low-pressure control switch. …
  5. Check the compressor.



What is a normal furnace cycle time?

10-15 minutes

With all that being said, if there are no extreme factors involved, the average run time for a furnace is 10-15 minutes per cycle. Your furnace may need to run two to three times an hour to maintain your desired temperature if your home has average insulation.