Why does my blower keep turning on and off?

If your blower is constantly turning on/off when the furnace isn’t heating… …you most likely have a bad fan limit switch. Your furnace fan limit switch is basically a control system that determines when the furnace blower assembly should turn on and off.

Why is my inducer motor constantly running?





If your inducer fan motor keeps on running all the time, it’s most likely due to a tripped safety such as the high limit switch. It could also be due to a bad control board that is “stuck” in the on position for running the inducer fan.

Can you run a furnace without an inducer motor?

Because the inducer motor helps your furnace run safely, the furnace will usually shut off if the motor won’t turn on. However, a bad inducer motor isn’t the only reason a furnace would shut off. A blocked gas vent flue or faulty pressure switch can have the same effect.

What happens if inducer motor stops working?

A failing inducer motor may create a noise shortly after a heating cycle begins. This could be a tapping noise, or a humming or whirring sound. If the unit will turn on but the blower motor is not turning on, there are a couple of ways to check if the draft inducer motor has gone bad.

How do I know if my inducer is bad?

Quote from the video:
Quote from Youtube video: And see if we get our voltage. All right so we're calling for heat. Right here these wires right here the hot and common wire 122 volts going to the inducer motor the problem is the inducer motor is

What does pressure switch open with inducer on mean?





Clogged air intake or exhaust



If the air intake or exhaust is clogged with debris, the pressure switch can remain in the OPEN position. This is because blockages prevent the inducer fan from creating negative pressure. A furnace pressure switch stuck open is a common problem for many homeowners.

How do you test an ECM inducer motor?

Quote from the video:
Quote from Youtube video: First we'll test voltage at l1. And – if there is no voltage at l1 and l2 check the breaker. If. We have voltage at l1. And l2 will check for voltage at the motor. Since we have high voltage at l1.

What causes inducer motor failure?

Most inducer motors failures are simply attributed to the older age of the furnace. In most cases, the internal bearings wear out and since the unit is a sealed unit, there is no way to repair the original motor. Instead the unit is simply replaced with a new one.

How is an inducer motor diagnosed?

Quote from the video:
Quote from Youtube video: Then I begin with we need to click the system selector switch on the thermostat to the heat position. This will also turn up the temperature setting of the thermostat above the room temperature.

How much does it cost to replace a furnace inducer motor?



Average Draft Inducer Motor Replacement Cost



The average furnace inducer motor cost is around $245, when the part is under warranty and you pay only the labor to have it installed. The replacement cost is $465 when the warranty has expired and you pay for the furnace inducer motor.

Is a blower motor the same as an inducer motor?

An inducer motor and blower assembly is definitely one of those parts you don’t think about until something has gone wrong with it. The inducer blower assembly consists of a small motor powered by electricity, a fan, an electrical box to allow connections, and a metal sleeve that surrounds the fan assembly.

How long should an inducer motor last?

Furnace inducer motors can have a life expectancy of 12-15 years. A replacement furnace inducer motor can cost around $800.

How do I know if my furnace gas valve is bad?



Here are some signs that indicate your furnace has a bad gas valve.

  1. A Gas Leak. This is a major indicator that something could be wrong with the gas valve in your furnace. …
  2. A Total Shutdown of the Furnace. …
  3. A Flooded Furnace. …
  4. Get Expert Services.


How do you reset the gas valve on a furnace?

If you turned off the power, turn it back on. Then, turn on the main gas supply and press the reset button. Hold it in for about 30 seconds, release it and adjust the main thermostat to its former setting.

How do you test a bad control board?

Use some tape to keep the switch pressed down. If your control board has 120 volts AC going into it, then it has power. If your control board has power, but it’s diagnostic light is not on, then the control board is likely bad and needs to be replaced. NOTE: You’ll need a multimeter to test for power in your furnace.