Why does my thermocouple keep failing?

Under constant exposure to a hot flame, a thermocouple wears down over time. Even a slight residue can make the thermocouple malfunction. The fix here is as easy as removing the thermocouple, cleaning it with a wire brush or something coarse (even an ordinary dollar bill works), and replacing.

Can a thermocouple fail intermittently?





Often when a Hot Water Heater stops working in the manner our client explained to me, it’s the thermocouple…. a safety device that has started to go bad, or has failed permanently. In this client’s case, the thermocouple was initially working intermittently, and then finally failed. Replacing it was an easy fix.

Why does my pilot light keep going out after replacing thermocouple?

If the pilot will lit but goes out after it reaches the temperature, it is the control valve. It happened to me. After the plumber replaced the control valve then it stays lit. You will have to order the control valve from the manufacturer.

How do I reset my thermocouple?

Press the reset button on top of the box to turn on the pilot light. Hold the reset button between 30 to 60 seconds to give the thermocouple time to heat up. Release the button to see if the pilot light goes out. The pilot light should stay on after the reset.

What stops a thermocouple from working?

Due to natural wear and tear, a thermocouple can get bent out of position, malfunction, become damaged, or coated in dirt or a build up of carbon. In any of these scenarios, the thermocouple will be unable to accurately sense the pilot light and consequently stop the heating operation.

How long should a thermocouple last?





Thermocouples can last up to 10 years if properly installed and maintained, while furnaces can last 15-20 years, although either may wear out sooner in multifamily units.

Can I bypass a thermocouple?

Realistically, you have just disabled the thermocouple, but you can also reach in and unclip it from its holding bracket where it meets the pilot light. In most cases it will be held on with a gravity clip, but some are held on with a screw that must be removed with a small screwdriver.

Will the pilot light stay lit if the thermocouple is bad?

A thermocouple senses the heat of the pilot and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner so the pilot light won’t stay lit.

How do I know if I need a new thermocouple?

A working thermocouple will give a reading of between 25 and 30 millimeters. If the reading is less than 25 millimeters, it should be replaced.

Are thermocouples interchangeable?



Precision Ceramics’ Materials in Thermocouples



Commercial thermocouples are interchangeable, economical, and supplied with standard connectors. Unlike most other temperature measurement devices, external form of excitation is not required for thermocouples because they are self-powered.

How many millivolts should a thermocouple read?

This measures the output of T’couple the readings must be above 17 to 18 millivolts. CLOSED CIRCUIT – This measures the millivolts used by the coil in the electromagnet. A rule-of-thumb is this reading should be roughly half of the open circuit.

What causes thermal switch keeps tripping?

The thermal switch can trip if the water heater is not getting enough air. Press the small reset button in the center of the thermal switch. If it’s tripped, you may be able to hear it click. Even if you do not hear the thermal switch click, try lighting the pilot using the instructions on the water heater’s label.

What is the most common thermocouple failure mode?



The most common failure mode for thermocouples is for them to fail open, this is known as thermocouple burnout. Burnout can result from a variety of reasons including the thermocouple experiencing a temperature in excess of that for which it was designed, metal fatigue, and oxidation.

What are the errors that occur that during the measurement using a thermocouple?

Because a thermocouple measures temperature differentials, any temperature fluctuations around the reference junction (cold junction), which has the known temperature, result in an erroneous temperature reading.

Is a thermocouple universal?

Universal Gas Thermocouple includes universal adapter fittings and is compatible with screw-in, push-in or clamp-type pilot burners. It is designed for gas furnaces and 30 mV systems. The element is built for reliability and long life.

How do you test a thermocouple?

Quote from the video:
Quote from Youtube video: If I take my wire and attach it to anywhere along the sheets of the probe. I attached to the sheath and I'm getting continuity this is a grounded thermocouple if this was an ungrounded thermocouple.

How do I know which thermocouple to buy?



How to choose a Thermocouple

  1. Determine the application where you will use the thermocouple sensor. …
  2. Determine the temperature ranges the probe will be exposed to. …
  3. Determine how important a fast response time is. …
  4. Consider any chemical, abrasion or vibration resistance. …
  5. Consider any installation requirements.


How do I know what size thermocouple to buy?

Universal thermocouples come in lengths from 15 to 36 inches. An 18 or 24 inch will suffice for all residential water heaters using universal kits. Almost all older waters heaters and many of the newer style units with a sealed burner compartment and a viewing window will use this thermocouple.

Does length of thermocouple matter?

The length of a thermocouple has no effect on its measurement accuracy or its ability to transfer the signal to the instrument. In other words, thermocouples do not experience “voltage drops” or power loss along its length as a high current power line might possess.