Can you have two check valves in series?

It consists of two check valves assembled in series. This employs two operating principles: firstly one check valve will still act, even if the other is jammed wide open. Secondly the closure of one valve reduces the pressure differential across the other, allowing a more reliable seal and avoiding even minor leakage.

What does a double check valve do?





A double check valve is a backflow prevention device designed to protect water supplies from contamination. It consists of two autonomously acting, spring-loaded check valves. It includes shutoff valves at each end of the piece and very small ball valves.

Where do you put a double check valve?

The Double Check Valve must be installed prior to the irrigation system and after the water meter. 2.1. Place the Double Check Valve within 2 feet of the meter box, (See note 5.1 below).

Are two check valves better than one?

Using a second check valve just in case the one on the pump fails is never a good idea. If the check on the pump fails, it must be replaced. Having a second check valve can mask the problem with the first check valve, and cause water hammer and possible contamination in the process.

How many check valves do you need?

The check valve will help your water system maintain pressure when the pump shuts off and also prevent backspin, upthrust, and water hammer. It is recommended that at least one check be installed in all submersible well pump installations. Many well pumps have built-in check valves.

How far above sump pump should check valve be installed?





Best height ( unless owner’s manual states otherwise) is two to three feet off of the top of the sump pit. This way your sump pump motor doesn’t have to work as hard as when your check valve is in lower position. It will open easier due to the reduced weight of water above it.

What is the difference between a dual check valve and a double check valve?

The difference between a dual check valve and a double check valve is that the double check valve can be tested and repaired with replacement parts while the dual check valve has no provision for testing.

Is a double check valve a non return valve?

Double check valves have two internal non return valve mechanisms, they are often needed as part of a plumbing system in order to comply with plumbing regulations.

Where should check valves be fitted?

Check valves are used in many different applications. For example they are often placed on the outlet side of a pump, to protect the pump from backflow. Centrifugal pumps, the most common type of water pumps, are not self-priming, and therefore check valves are essential for keeping water in the pipes.

Is a swing or spring check valve better?



The most significant advantage of swing check valves is their low cost, which allows them to work within a wider range of project budgets. They also provide large flow capacity. Since this valve cannot support downward vertical flow, there are limits to the types of systems it can serve.

What are the 5 types of check valves?

Most common types of Check valves are swing, lift (piston and ball), butterfly, stop and tilting-disk.

Which is better foot valve or check valve?

As the name implies, a ‘foot’ valve goes at the end of the pump. As a result, it only has one thread instead of two. Therefore, if you need a valve that goes on the end of your pump, a foot valve is an ideal choice.

Can you use a check valve horizontally?



Check valve can be installed in horizontal or vertical piping runs, with the flow running upward.

Can a foot valve work horizontally?

Different Types of Foot Valves

For spring-type foot valves, which can be installed vertically and horizontally, a poppet is held in place with a spring. When pressure occurs, the spring forces the poppet to return to the closed position. Flapper-type foot valves operate with the help of gravity.

Does a foot valve act as a check valve?

A foot valve is a type of check valve that is typically installed at a pump or at the bottom of a pipe line (hence the name). Foot valves act like ball check valves, but have an open end with a shield or screen over it to block debris from entering the line.

Does a check valve go before or after a pump?



The check valve must be installed at the outlet of the pump and in front of the outlet control valve for maintenance. Generally, the first outlet of the pump is the soft connection (shock absorber), the next is the check valve, and then the block valve.

Does a pressure tank need a check valve?

What Does A Water Check Valve Do? Check valves are designed to permit water to flow in one direction and are a requirement on all submersible pump installations. Their job is to prevent water in the column above the pump and in the pressure tank from draining back into the well when the pump shuts off.

Is foot valve is a two way valve?

A foot valve is a type of check valve that only allows one-way flow. Use foot valves when you have situations that need a pump, such as when water needs to be extracted from an underground well.

Why are foot valves used?

Why is a foot valve used on a pump? Without a foot valve water would flow back out of your suction line when a pump is turned off. A foot valve helps to stop your pump from burning out by keeping it primed and is a very inexpensive way to do so.

How many types of foot valves are there?



Foot Valve Types

There are three types of foot valves. The micro-flow system valves are used in direct push technology micro wells and multi-level well installations. These are usually made of stainless steel and are either of fluorotherm (FEP) or high-density polyethylene (HDPE) tubing.