What size is water heater vent pipe?

For most installations, a 40–gallon water heater with a 3–inch outlet on the draft hood is required to have a vent connector that is a minimum of 4 inches in diameter. That means the vent connector has to increase in size by 1 inch.

How do you seal the gap around a water heater vent pipe?





These gaps should be sealed with lightweight aluminum flashing and special high-temperature (heat-resistant) caulk. Before you push the insulation back into place, build a metal dam to keep it away from the pipe. Use the same technique for masonry chimneys.

How do you secure a hot water heater vent pipe?

Draft hood and gas water heater vent pipe connections



The connection between the draft hood and the vent pipe should be secured with sheet metal screws – three per connection on a single wall pipe are recommended. DO NOT use regular duct tape to secure or seal connections.

How do you secure a water heater draft hood?

Push-in Type with screws: Most draft hoods are designed to be secured with screws (which are provided). Align the legs of the draft hood with the slots in the top of the water heater. Insert the legs into the slots, then secure them with screws as described in your installation manual.

How do you install a gas water heater vent?

Quote from the video:
Quote from Youtube video: And comply with the electrical requirements.

What is code for venting a hot water heater?





The water heater must be vented in accordance with the section “Venting of Equipment” of the latest edition of the National Fuel Gas Code: ANSI Z223. 1/NFPA 54 in the United States and/or Section 7 of the CAN/CSA B149. 1 Natural Gas and Propane Installation Code in Canada, as well as applicable local building codes.

How do you seal around an exhaust pipe?

How to Seal My Furnace Vent Pipe

  1. Clean the area. Remove any dirt or debris from the area around the vent. …
  2. Apply sealant. You can choose either caulking or a foam sealant to seal your vent pipe. …
  3. Clean it up. If using caulking, you may wish to smooth it out after it has been applied.


What do you put around a flue pipe?

Sealing Flues: Techniques

  1. Furnaces and water heaters: should have pipes made of galvanized metal and sealed with aluminum flashing and high-temperature silicon caulking.
  2. Chimney: should have pipes made from masonry or metal and in similar fashion, be sealed with aluminum flashing and high-temperature silicon caulking.

How do you seal exhaust vents?



Seal holes in the fan housing with caulk, sealing putty, or metal tape. Install the fan then seal around the fan with caulk or canned spray foam. Seal the exhaust duct to the fan box with approved metal tape or mastic. Seal around the exterior fan duct vent with caulk or a pre-made exterior wall gasket.

What does a draft hood connector do?

The draft hood connector connects Type B gas vent directly to an appliance draft hood. The flexible inlet can be shaped to fit oval draft hood outlets.

Can I use PVC to vent gas water heater?

A standard will be needed for plastic flue pipes that should include a temperature gauge and a high limit probe. Then PVC, CPVC and polypropylene flue gas piping can be safely used on high efficiency boilers and water heaters.

How does a draft vent work?



It connects to the vent that carries the exhaust out of the house. The openings under the draft hood allow ambient air to be drawn into the vent to relieve pressure at the burner. As the hot gases rise out of the middle of the tank, the gas mixes with air and it is all carried up through the vent and out of the home.

What does the draft diverter do in the case of a downdraft in the flue pipe?

The draft diverter addresses this issue by preventing the backdraft of exhaust gases into the room. It gathers nearly all combustion products from the primary flue, diverting them to the secondary flue, which then vents them safely outside.

What is the air that is drawn into the draft hood called?

Dilution air

Dilution air is that air which is drawn in through the draft hood or draft diverter relief opening.

What is Type L vent?



Type L vents are designed for venting approved oil-fired and natural-gas appliances that produce draft hood flue gasses that do not exceed a temperature of 570º F (299º C), or 926º F (299º C) for 10 minutes in an over-fire situation. The minimum clearance from combustible materials is generally 3 inches.

What is Category 3 vent?

Category III refers to positive vent pressure which is created by exhaust blowers in unit heaters. These vent systems must be constructed of AL29-4C® stainless steel, contain gaskets for sealing, and have a built in mechanical locking band among other requirements.

What is a B vent?

B vent: This approach, also called natural vent, pulls air from indoors for combustion and vents it outside. It features a chimney with a double wall pipe which runs from the fireplace to outside of the home. Homeowners can purchase fire boxes inside another box.

What is Type C vent?

Only type C vents are used. galvanized pipes are single walled galvanized pipes. Venting gas or oil is what they are used for. Toxic fumes can be caused by using a C vent with solid fuel appliances.

How do you connect B vent pipe together?



The new and improved AmeriVent Type B gas vent features a quick disconnect system.

  1. To Connect: Snap-lock pipe and fittings together or align the seams, push together, and twist at least 1” to lock.
  2. To Disconnect: Simply realign the seams and pull apart.

How hot does B vent pipe get?

Properly installed, the vent cannot come apart through vibration, and offers protection against vent failure or fire hazard. Type B Gas Vent is designed for negative pressure applications and flue gas temperatures not exceeding 400°F above ambient for Category I appliances.