It’s typically recommended that you go with a 2″ PVC pipe for the vent. This is according to the uniform plumbing code (UPC). It may not be enough, depending on how many fixtures you are trying to run off the vent.

What size should the vent pipe be?

11/4 inches





Vent pipes shall not be less than 11/4 inches (32 mm) in diameter. Vents exceeding 40 feet (12 192 mm) in developed length shall be increased by one nominal pipe size for the entire developed length of the vent pipe.

What PVC fittings should be used for drain waste and vent pipes?

DWV drainage pipe is used for drain, waste and vent or DWV the first letter in each word. Both fittings are made of PVC they can be Schedule 20, 40 or 80 witch is the thickness of the fitting the higher number means the stronger the fitting.

What size is PVC sewer pipe?

The standard size for a sewer drain leading away from a toilet is 3 inches in diameter.

What type of pipe is used for vent?

Cast iron, galvanized steel, galvanized wrought iron, copper, brass, Schedule 40 ABS DWV and Schedule 40 PVC DWV are some commonly used approved materials.

Can I use Schedule 40 PVC for drain?





Schedule 40 is ideal for above-ground vent lines and sewer lines in homes and has a thinner wall thickness than schedules 120 and 80.

Can I use Schedule 40 PVC for sink drain?

He uses thick “schedule 40” plastic (PVC or ABS) parts that are “welded” together with solvent cement for sink drain plumbing. An assembly like this will last forever, no matter how times you bash it with the wastebasket.

How do you vent a sewer line?


Quote from Youtube video: And the air comes into this and it is it is sucked down this pipe. Extremely fast you'd be stunned how fast the air goes through this pipe. And so these vent pipes supply the much-needed.

How do you get sewer smell out of vent pipe?

While you can’t stop the creation of septic and sewer gases, you can eliminate the odor that is caused as they exit the roof vent pipe or septic tank vent by installing a Wolverine Brand® carbon filter on top of your sewer vent.

Can a toilet vent be downstream?



Can a toilet vent be downstream? Never. A toilet vent always should be upstream. The purpose of the pipe is to allow sewer gases and water from entering your house.

Should toilet vent be upstream or downstream?

A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer’s gases to escape from the house’s roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.

How far can a vent be from toilet?

6 feet



According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

Does a vent stack have to go straight up?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

What is the difference between a sanitary tee and a vent tee?

A sanitary tee is a plumbing fixture that allows liquids to drain while also allowing the plumbing system to vent. The fitting resembles a normal tee fitting; the sanitary tee, however, when viewed from the side will have a definite downward sweep to the center inlet.

Can you put a 90 in a sewer line?

You should design your wastewater pipes in a similar manner, for the most part. It’s a bad plumbing practice to have a hard 90-degree bend in a horizontal drain line that’s buried in a slab or otherwise hidden.

Can a vent pipe be horizontal?



2. Can Vent Pipes be Horizontal? There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line.

How close does a plumbing vent need to be?

For a 1- 1/2-inc pipe the vent must be 42 inches away at the most while a 2-inch pipeline must have an optimum distance of 5 feet. For pipelines that have a diameter of 3 inches the range is 6 feet and for a 4-inch pipe the most it should be far from the vent is 10 feet.

How high does a drain vent need to be?

6 in.

The International Plumbing Code requires plumbing vent pipes to be at least 6 in. Section 905.5 deals with vent connections and grades above a roof. Vent pipes must be at least 12 in. It is away from a vertical surface.