There is likely a fault on the neutral associated with one of the circuits. It’s also possible that there is a faulty or mis-wired MWBC (explanation of MWBC here). You could try disconnecting the wires from the breakers in the service panel and testing directly from the breaker to the neutral and groundneutral and groundNeutral is a circuit conductor that normally completes the circuit back to the source. Neutral is usually connected to ground (earth) at the main electrical panel, street drop, or meter, and also at the final step-down transformer of the supply.

Why do I have 240 volts on the neutral?

The grounded (neutral) conductor is connected to the center of the coil (center tap), which is why it provides half the voltage. Therefore, if a device requires only 240V, only two ungrounded (hot) conductors are required to supply the device.

Why does my neutral wire have voltage?





The voltage you are seeing on the neutral wire is conducting through that other load from the hot. Your voltage tester is detecting voltage without drawing current so the resistance of the other load is not seen. Try disconnecting/turning off all other loads on that circuit.

Why is my neutral wire showing hot?

If the neutral is disconnected anywhere between the light bulb and the panel, then the neutral from the light to the point of the break in the neutral will become hot (and the device will be unpowered, because no current will be flowing through it). Look for a disconnected neutral.

Should there be voltage between hot and ground?

To check if neutral and ground are switched, measure hot-neutral and hot-ground under load. Hot-ground should be greater than hot-neutral. The greater the load, the more the difference. If hot-neutral voltage, measured with load on the circuit, is greater than hot-ground, then the neutral and ground are switched.

Why do I have voltage when switch is off?

Just to recap, a “phantom voltage” is where a wire from a switch to a light or outlet runs next to a permanently live wire, when the switch is off, the AC voltage in the other wire can induce a voltage in the switched-off wire.

Does single-phase 240V have a neutral?





Residential 240V outlets usually have three or four connectors, which provide two hot 120V wires and either a ground wire, a neutral wire, or both (see Figure 3). The neutral wire provides a way for the appliance to use just one of the hot wires for 120V appliances like a clock or fan.

What is a floating neutral in wiring?

A “floating” neutral occurs when the connection to the ground breaks or becomes loose, which causes the neutral bar to “float.” This can happen in your panel or between the utility and your electric panel. It can be caused by a mechanical issue or other issues like rust or corrosion.

Should there be continuity between hot and neutral?

If you are testing from one of the phase wires on the load side of the main breaker with it off to the neutral you will get a reading if any of the branch circuit breakers are on and connected to loads. Turn off all of the breakers and check again it should read no continuity. It’s a new house.

Does neutral wire carry power?

Neutral wire carries the circuit back to the original power source. More specifically, neutral wire brings the circuit to a ground or busbar usually connected at the electrical panel. This gives currents circulation through your electrical system, which allows electricity to be fully utilized.

What does ghost voltage indicate?



As you may know, ghost voltages occur when your test (which isn’t receiving power) reads voltage from a nearby electrical source. Usually, this is due to extra and unused wiring in the conduit being tested as it runs along other wires that are receiving power.

Why do I have voltage on my ground wire?

Stray voltage occurs when electricity “leaks” from the black wire directly to the white or ground wires before passing through the device to be powered. These leaks produce only small amounts of electricity. Direct contact between the white and black wires would “short” the system and blow a fuse or circuit breaker.

Why am I getting 120 volts on my neutral?

If you have a neutral wire removed from the neutral bus bar in your panel it is possible to see 120VAC on that wire if the circuit breaker for that circuit is turned on and there is a load connected to the circuit and load device is also turned on.

Should there be any voltage between neutral and ground?



Some neutral-to-ground voltage should be present under load conditions, typically 2V or less. If the voltage is zero with a load on the circuit, then check for a neutral-to-ground connection in the receptacle, whether accidental or intentional. Reversed neutral and ground wires.

Can two hot wires share a neutral?

What is a multiwire branch circuit? A multiwire branch circuit is a branch circuit with a shared neutral. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

What happens if neutral and live touch?

In an electric iron being used in a household, the plastic insulation of live wire and neutral wire in the connecting cable gets torn. Due to this, naked live wire touches the naked neutral wire directly and the electric fuse of the circuit blows off.

Can you touch the neutral wire without getting shocked?

Now, we know that neutral is always connected to the ground or earth. So when touching the neutral wire standing on the ground there is no voltage applied to our body, therefore no current flow through our body and we do not get the electric shock.

Can you get a shock off a neutral wire?



The neutral wire does have current going through it. However, we do not get shocked when we touch something with current going through it, we get shocked when current goes through us. In this case all of the current that enters one end of the section of wire we are touching also leaves the other end.

What happens if neutral wire touches ground?

In Short if neutral wire touches a earth wire,

An earth wire carrying load current is a risk of electric shock because a person touching this earth may present an alternative path for the load current and thus the risk of electric shock.

Can a hot and neutral wire touch?

A short circuit happens when a “hot” wire (black) touches another hot wire or touches a “neutral” wire (white) in one of your outlets. When these two wires touch, a large amount of current flows, creating more heat than the circuit can handle, so it shuts off.

Can neutral and ground be connected together in main panel?



The answer is never. Grounds and neutrals should only be connected at the last point of disconnect. This would be at main panels only.