What causes a weak flame on a furnace?

How Does It Happen? Flame rollouts in gas furnaces and boilers are caused by a high concentration of combustion gases inside the combustion chamber. Normally, these inflammable gases are exhausted from the furnace through the flue passageways in the heat exchanger, then up the vent to the exterior of the home.

Why do I have to keep resetting my furnace?





A furnace reset button is an important feature included with your HVAC system. Designed to quickly shut the unit off, the function is key to safely heating your home. If your furnace reset button keeps tripping, it’s likely that your furnace is overheating. This may indicate a need for furnace repair services.

What causes weak flame on intertherm furnace?

Sometimes, if the flame sensor is dirty, it will fail to detect a flame. Try cleaning the flame sensor with a fine abrasive pad. If the furnace still doesn’t heat, replace the flame sensor. The control board regulates the power supply to all of the components of the furnace.

How long should furnace burners stay on?

With all that being said, if there are no extreme factors involved, the average run time for a furnace is 10-15 minutes per cycle. Your furnace may need to run two to three times an hour to maintain your desired temperature if your home has average insulation.

How do you trick a flame sensor?

Luckily, making such a check is very easy:

  1. Take a multimeter with microamps (µA) measuring system.
  2. Keep the furnace system turned on.
  3. Connect it to the wire that is leading to the gas valve.
  4. Connect the other side of the multimeter to the sensor terminal.
  5. Take the lead away from the flame sensor.

How do I clean my furnace flame sensor?





The Process of Cleaning a Furnace Flame Sensor

  1. Turn off the furnace power.
  2. Turn off the gas valve.
  3. Remove the furnace flame sensor.
  4. Clean the sensor with an emery cloth.
  5. Return the flame sensor.
  6. Restart the furnace.

How many times can I hit the reset button on my furnace?

Don’t hit “reset” more than twice. The process pumps oil into the burner chamber, where it can accumulate if you have no ignition. Then when the furnace finally does start, it can do so explosively. So if the button won’t reset, or quickly pops up again, it’s time to call a professional repair service.

How long does it take a furnace to reset?

Leave the breaker(s) off for at least 10 minutes while the system is off and “rebooting.” After 10 minutes have elapsed, go back to the breaker box and flip the HVAC breaker(s) back on.

Why does my furnace only work after power reset?



You may have a faulty sensor, sticky motor, bad controller board, too many closed dampers, a blocked air return, incomplete combustion, cracked heat exchanger, blocked condensate line, etc etc. some of these things are life-critical situations.

Do furnace burners cycle on and off?

When your furnace turns on and off, also called short cycling, it’s generally the result of overheating. The furnace gets too hot and automatically shuts off. Then, once it cools a bit, it’s able to restart, until it overheats again. If your furnace is overheating, that means it’s overworked.

How long is too long for a furnace to run?

Industry research shows some expected time frames for how long a furnace runs during a particular cycle. Running 10 to 15 minutes per cycle seems acceptable. So is running as long as 20 minutes. Even running every seven or eight minutes may not be a problem, as other factors could lead to more frequent cycling.

Why is my furnace coming on every 5 minutes?



Short cycle time: 2-5 minutes.

Your furnace has a part called a high-limit switch. If the furnace gets too hot, the switch shuts down the furnace. A dirty filter prevents a flow of fresh, cool air into the furnace to be heated and dispersed. Without the fresh air, it will quickly overheat.

Why does my furnace keep short cycling?

A dirty air filter is the most common cause of short-cycling. If your air filter is clogged with dirt, it won’t allow proper air flow to the heat exchanger. That can cause the furnace to overheat and forces the high limit switch to ride to the rescue by shutting the furnace off.

Why is my furnace kicking on every 10 minutes?

It cycles off because an inner safety is getting overheated from inadequate airflow. Either get a smaller furnace or enlarge the duct system to move the amount of air needed by the furnace.

Why does my furnace keep shutting off after a few minutes?



If your furnace keeps shutting off, it could be due to low airflow. There are several indirect issues that cause low airflow. Dirty Air Filters. If you don’t change your air filters often enough, the filters will become dirty and clogged, which means the heat exchanger retains heat and eventually causes it to overheat.

Why won’t my furnace shut off?

On your thermostat, look for the fan settings. There should be two, “ON” and “AUTO.” If it seems like your furnace won’t turn off, the thermostat may be set to “ON” for the blower. Toggle the switch to “AUTO” so your furnace’s blower fan only runs during a heat cycle.

Why does my heater keep running after it has reached the set temperature?

When your furnace keeps running after the temperature has been reached: Check the blower motor – Your forced air heating system uses a blower to push air through ducts and into your living space; sometimes, the blower runs at the same time that your furnace is heating the air, but sometimes it runs on its own.

Why is my furnace blowing cold air and won’t shut off?

If it’s cold, that means that your furnace is not running but the air handler is still blowing air. If the air is hot, obviously, the furnace is on. If the air is cold, the first suspect is the thermostat. Check to make sure the fan is set to AUTO, and not to ON, which would cause it to run continuously.