Your water heater’s relief valve can start leaking for one of two reasons: either the valve was triggered to open because of excessive temperature or pressure, or the valve itself is faulty. In the first case, the valve will drain water out of the discharge pipe as explained above.

Why is my new pressure relief valve leaking?

The most common cause of a temperature and pressure relief valve leaking is simply malfunction due to age. After years of use, the t&p valve can be too old to work properly. In this case, simply replacing the t&p valve should fix the problem. If the temperature and pressure relief valve is faulty, it can also leak.

Why is water coming out of my water heater pressure relief valve?

When you see water coming out from the water heater release valve, there are two most likely causes. The relief valve is working the way it’s intended, and water drained to reduce the pressure inside the tank. There’s a problem with the valve, such as a faulty seal, and the water is unintentionally leaking.

How do I stop my pressure relief valve from leaking?

Common Fix For a Leaking Temperature Pressure Relief Valve

  1. Turn off the water heater breaker.
  2. Shut off your water.
  3. Empty the water heater by draining the bottom and water inside your home.
  4. Remove the TPR valve and discharge tube by unscrewing with a wrench.
  5. Replace with a new TPR valve and discharge tube.

Why is my brand new hot water heater leaking?

If your water heater was installed in a hurry or has a loose or otherwise faulty fitting, a poor connection could be to blame for your leak. In addition, plumbing materials can experience damage from issues such as expansion and contraction caused by temperature changes, wear and tear caused by pressure, and more.

Why is water dripping from my overflow pipe?

When an overflow pipe is dripping or running with water, one of the most common causes is a problem with a float valve. Float valves are found in toilet cisterns, cold water tanks and central heating feed and expansion tanks.

How much water should come out of pressure relief valve?

Verify the proper valve is installed



The TPRV on a water heater is set to discharge at 150 PSI or 210° Fahrenheit. These numbers will be printed right on the valve, or on a tag attached to the valve.

Why does my pressure relief valve keeps opening?

Quote from the video:
Inside the tank gets too high the relief valve will open and release water preventing the tank from exploding. If the relief valve opens intermittently or even daily.

What causes too much pressure in a water heater?

There’s a safety valve in every water heater, called the Temperature and Pressure Relief Valve, or a T&P relief valve. In short, when the temperature or pressure of the water heater gets too high, the valve opens, and releases water that’s causing the increase in pressure.

How often should pressure relief valves be replaced?

every three to five years

Repair every three to five years.

What is code for water heater pressure relief valve?

Item 10 requires the relief valve to terminate no more than 6 inches (152mm) above the floor surface, a waste receptor or floor drain in order to prevent hot water discharge from being directed onto a building occupant that may be nearby.

Where should pressure relief valve drain to?

The valve should be connected to a discharge pipe (also called a drain line) that runs down the length of the water heater tank. This pipe is responsible for routing hot water released from the TPR to a proper discharge location.

Can water heater relief valve drain into pan?

The terminal end of the pipe shall not be threaded. Discharge from a relief valve into a water heater pan shall be prohibited.

Where is water heater relief valve?

A temperature pressure relief valve is a valve that’s located somewhere near the top of your water heater. The valve has a lever that can be lifted up or down and a discharge pipe that runs from the valve straight down to the bottom of your water heater.

How do you test a water heater relief valve?

Quote from the video:
Simply place a bucket beneath the discharge tube. You just want to flip open the relief valve. And let it run for about five seconds to make sure it opens fully.

How does a relief valve work?

A relief valve works by providing an excessively pressurized fluid an open path to tank with the goal of reducing work port pressure. As fluid pressure begins to rise, force from that pressure is applied to the bottom of the spool or poppet, similar to what occurs to the piston of a cylinder.