When you see water coming out from the water heater release valve, there are two most likely causes. The relief valve is working the way it’s intended, and water drained to reduce the pressure inside the tank. There’s a problem with the valve, such as a faulty seal, and the water is unintentionally leaking.

How do I stop water coming out of my pressure relief valve?

Common Fix For a Leaking Temperature Pressure Relief Valve

  1. Turn off the water heater breaker.
  2. Shut off your water.
  3. Empty the water heater by draining the bottom and water inside your home.
  4. Remove the TPR valve and discharge tube by unscrewing with a wrench.
  5. Replace with a new TPR valve and discharge tube.

Why does my hot water heater leak from the top?





A very common cause of gas hot water heater leaking from the top is a malfunctioning or damaged temperature and pressure valve, also known as a temperature-pressure relief valve. You may have to replace it or check the heat and pressure inside the tank.

Is it normal for water to come out of pressure relief valve?

Pressure relief and safety relief valves will leak if the valve isn’t fully closed. This is a common problem in industrial settings where environments are often dusty or dirty. If there is any debris in the valve, it can obstruct the valve from fully closing, causing it to leak.

How do you stop a water heater leaking from the top?

1) Loose fittings

You can take a wrench and try to tighten the fittings. This might completely stop the leak, solving your problem. Also, corrosion in this area is not uncommon. Corrosion will be best dealt with by replacing the fittings.

Why does my hot water heater overflow keep discharging water?





Causes of Excess Pressure in a Water Heater

Since water expands as it’s heated, higher-temperature water occupies more volume, which, in the confines of a water heater, results in increased pressure. If the pressure increases too much, your relief valve will activate, releasing water through the drain pipe.

Why is hot water coming out of my overflow pipe?

A leaking overflow pipe can indicate that: The temperature setting on your water heater is too high. There is an issue inside your tank causing pressure to increase beyond the T&P valves threshold. The T&P valve is not “set” properly allowign the valve to remain partially open.

What is the valve on top of water heater?

On the side or top of your water heater tank is a valve connected to a metal or plastic discharge tube pointing downward. The valve is called a T&P valve, or TPR valve, for “temperature and pressure relief.” If all goes well, a TPR valve never gets used intentionally except during testing.