What wire do I need to wire a subpanel?

This is typically a three-wire cable with three insulated conductors plus a bare copper ground wire. The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example.

Does wire to a sub panel need to be in conduit?





Unless you area requires conduit for wiring in dwelling units there is no NEC issue with running a cable as a feeder. It must be a 4 wire cable to the sub panel.

How do you wire a 120 volt 30 amp sub panel?

Quote from the video:
Quote from Youtube video: We've got a three wire with a ground number 10 set that is feeding our panel for 30 amps. And when I say number 10 it's what number 10 is the wire that it takes to feed a 30 amp subpanel.

How far can you run a wire for a sub panel?

The panel must be easily accessible, so don’t install it too far above the floor; 4.5 to 5 feet is about right. The cable you run from the main panel to the subpanel also depends on the amperage rating. You can use 10 AWG, three-conductor wire for a 30-amp panel, but for a 60-amp one, you need 6 AWG wire.

What size conduit do I need for 100 amp sub panel?

What Size Conduit You Need for 100 Amp Service. A 100 amp service will need a minimum of 1.25 inches, schedule 40 or 80 PVC grey electric conduit.

Can I use aluminum wire for the ground to a subpanel?





YES you can use #4 Al as your ground. Your 1AWG Al is good for a 100 AMP feeder (actually 110). From NEC 250.122 this requires an #8 CU or #6 Al ground wire as a minimum (or 6CU and 4 Al if you are really running a 110Amp Feeder).

Does a subpanel need to be grounded to the main panel?

Most panels come with a bar joining the two, which is easily removed. Code requires subpanels to have a ground connection that’s independent of the main panel’s.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can I run a 100 amp sub panel off 200 amp main?

Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

What wire size do I need to go 100 feet for a 100 amp service to a workshop?



For a 100 ampere circuit, the conductors will likely be required to be 3 AWG copper or 1 AWG aluminum.

Can you run a 100 amp sub panel off a 100 amp main panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.

Can a 60 amp breaker feed a 100 amp sub panel?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

What size wire do I need to run a 60 amp subpanel?



In short, the wire size for a 60 amp sub-panel 150 feet away is 3 AWG gauge wire.

What is the 6 throw rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

Can you run a sub panel off of a sub panel?

Answer: Yes. The main electrical service panel is where branch circuits originate.

Can you wire a subpanel with 3 wires?

Another way to wire a subpanel was with a three-wire feed; two hots and a neutral, with grounds and neutrals connected together at the subpanel. In this case, the grounds and neutrals have to be connected together.

How many circuits can be on a 60 amp subpanel?



Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.