Yes. You can feed two panels, say 100 amps each, with a single 100 amp feed. Another solution is to bring the feed to a junction box and split it. I’ve forgotten the exact rule but you can drop the smaller wires down to the panels a short distance as long as they terminate in appropriately sized breakers.

Can you run 2 sub panels off the main panel?

You can add as many subpanels as you need providing the combined electrical demand is below 160 amps. If all the circuitry was operating at once, the electrical service could become overloaded.

Can you feed two circuits one breaker?





The short answer is yes, if you have breakers that accept two wires, or if you pigtail them in the panel and connect a jumper to the breaker.

How many circuits can I run off a 50 amp sub panel?

A single receptacle has a maximum power draw of 1.5-amps, so, only use 26 outlets at most for a 50-amp breaker (40-amps ÷ 1.5-amp = 26.67 outlets).

Can a subpanel feed another sub panel?

Yes, it’s redundant, but it’s still required. The wire feeding the new subpanel must be protected from overcurrent by an appropriately-sized breaker. It can be at either end – in the old subpanel or in the new subpanel – or at both ends.

How many sub panels can you run off a 200 amp service?

200 AMP Service – Feeding 3 Sub-Panels – Wire Size and Set Up Help Needed.

Can I put 2 100 amp sub panels on a 200 amp service?





Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

What is a piggyback breaker?

In the space of one 1″ breaker, fits two breakers side-by-side (Twin) or over/under (Piggyback).

Is Double lugging against code?

Double lugged neutrals are a defect, were never up to code, and should be corrected. The good news is that it should take an electrician about 1 minute to fix it!

Why would you double tap a breaker?

A double tapped breaker is basically two wires under one circuit breaker that is designed for one wire. You can see what this looks like in the picture above. The issue with double tapping is you could technically have a loose connection or an overloaded breaker since the breaker is not designed for two wires.

Can I run a 100 amp sub panel off a 100 amp sub panel?



Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

What is the 6 breaker rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

How many wires do I need to feed a subpanel?

This is typically a three-wire cable with three insulated conductors plus a bare copper ground wire. The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example.

Can you feed a 100 amp sub panel with a 60 amp breaker?



You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Can you feed a 100 amp sub panel with a 50 amp breaker?

Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

How do you hook up a subpanel to a circuit breaker box?

Quote from the video:
Quote from Youtube video: The wire. Into the sub panel from the main panel. So we'll be running our six gauge ground wire. And our feeder wire next this is three gauge like I mentioned earlier anything six gauge or smaller.

Can you run a 200 amp sub-panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How many breakers can I put in a 30 amp subpanel?



The amount of current that is required for the connected loads can only be supported by a 30 Amp sub-panel. The maximum quantity of branch circuits can be determined with a load calculation. Two 15amp breakers or one 15amp and one 20amp can be used on a 30amp circuit.

What size breaker do I need for a sub-panel?

Based on your question, since you will be having a subpanel, you want the breaker feeding the subpanel to be sized for the subpanel or slightly smaller. So if you purchase and install a 200A subpanel, then the breaker should be 200A. If you use a 125A subpanel, then use a 125A breaker.

How many breakers can I run off a 60 amp sub panel?

The NEC does not allow installing panels rated below 100-amps as the main electrical panel for the house. Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

Can a 60 amp breaker feed a 60 amp sub panel?

Probably not. While the 60A breaker’s primary job is to protect the wiring between the panel and the subpanel, you can have breakers totaling more than 60A in the subpanel.