Can I run a 60A sub-panel off of another 200A sub-panel? Yes, you will need to run a four conductor six gauge wire.

Can you run a sub panel from another sub panel?

Answer: Yes. The main electrical service panel is where branch circuits originate. A branch circuit consists of the circuit conductors between the final over-current device protecting the circuit and the lights, receptacles and equipment supplied by the branch circuit.

Can you put a 60 amp breaker in a 200 amp panel?





In general, a 200-amp panel should handle no more than 160 amps at once. It’s important to note that people can have 300 or even 400 amps worth of breakers in a 200A panel, as they don’t use all circuits at the same time. Calculating how many circuit breakers you need is also dependent on your home electrical loads.

How big of a sub panel can I run off a 200 amp service?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

Can a 60 amp breaker feed a 60 amp sub panel?

You don’t have to use a 60 amp panel. Use a 100 amp panel and feed it from a 60 amp breaker. The sub panel only has to be rated at or above the breaker size feeding it.

Can you run a 100 amp sub panel off a 100 amp subpanel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

How do you hook up a subpanel to a sub panel?





Quote from the video:
Quote from Youtube video: Together in the neutral bar because in the main panel the neutrals and grounds are bonded together by a bonding strap.

What size wire do I need for a 60 amp sub panel?

4-gauge wire

While it’s common to use a 6-gauge wire for 60-amp breakers in practice, it’s best to use a 4-gauge wire if you’re installing a 60-amp subpanel. 60-amp breaker panels controlling several circuits can draw a max of 60 amps before the subpanel breaker trips.

What size wire do I need to run 60 amps 200 feet?

For 60 ampere breakers, electricians and professionals suggest using a wire size gauge ranging from 6 AWG to 4 AWG. All household wires have a rating of at least 600V, so only amperage really matters when it comes to determining wire gauge. Therefore, the wire size for 60 amp 220v, for example, is still 6 to 4 AWG.

Can you run a 60 amp sub panel?



Quote from the video:
Quote from Youtube video: I have installed it's a 60 amp breaker. So I'm feeding a 60 amp subpanel. And one thing to kind of keep in mind and when you're planning all this is breakers protect downstream wires.

How many breakers can I run off a 60 amp sub panel?

The NEC does not allow installing panels rated below 100-amps as the main electrical panel for the house. Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

Can I feed 100 amp sub panel with 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Does a 60 amp sub panel need a main breaker?



Your subpanel does not need a main breaker if it’s in the same building. If it is in an outbuilding, you need a disconnect switch, and the breaker will suffice but its size doen’t matter.

Can you run a 100 amp sub panel off a 200 amp main panel?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

Can you feed a 100 amp sub panel with a 50 amp breaker?

Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

What do I need for a 60 amp sub panel?

It is common to wire 60-amp breakers with 6-gauge, 3-conductor wire because an appliance that needs a 60-amp breaker rarely draws the full 60 Amp. It’s a good idea to connect a 60-amp subpanel to the main panel with 4-gauge wire.

What wire size do I need to go 100 feet for a 60 amp service to a workshop?



What size wire should I use for a 60 amp subpanel? You can get away with 6 AWG when you have a short run of wire, however, due to voltage drop, if you ever decide you want to go more than 100 feet then a 4 AWG is the size you should choose.

What can I run on a 60 amp service?

Sixty amps may not be enough to service a home with an electric stove, oven, clothes dryer, air conditioner, and so on. But some homes operate just fine on 60 amps. These homes usually have a gas stove, and sometimes a gas clothes dryer as well.

How much does it cost to install a 60 amp sub panel?

The average cost of installing a subpanel is between $400 and $1,750, depending on the amperage and number of circuits installed.

When did 200 amp service become standard?

’80’s



In the ’60s and ’70s, 100-amp service became more common – better than earlier service, but still low by modern standards. In the ’80’s, 200-amp became more common to accommodate the growing electrical demand of the various equipment in the home.

How much does it cost to upgrade subpanel?

A low-amp subpanel costs from $500 to $1,000 while a 200-amp panel upgrade runs up to $4,000. Total costs depend on the type of home, the number of circuits, and the amperage.