How many amps does a bathroom exhaust fan draw?

Generally, bathroom exhaust fans use a 15-amp circuit breaker. Although for exhaust fans with heaters, a 20-amp circuit breaker is preferable as it consumes more power. The usual requirement for a regular exhaust fan is 1 watt per 3 CFM or 5 CFM (Cubic Feet Per Minute).

Does a bathroom fan need its own circuit?





Bathroom Circuits



If the vent fan has a built-in heater, it must have its own 20-amp circuit. This is called a “dedicated” circuit because it serves only one appliance or fixture. Heat lamps, wall heaters, and other built-in heating appliances may also require dedicated circuits.

Can I use 14 2 wire in a bathroom?

Bathrooms typically require dedicated 20A circuits, but that has no bearing on how much power your fan consumes. As long as the voltage is correct the fan will only draw what it needs assuming the wiring to it has sufficient capacity, which both 12/2 and 14/2 do.

Can a bathroom fan be on a 15-amp circuit?

A 15-amp circuit breaker is used by most bathroom fans.

Do bathroom outlets require 20 amps?

The NEC requires that all outlet receptacles in a bathroom be GFCI protected. Outlet circuit must be 20 amps: The outlets in a bathroom should be served by a 20-amp circuit, separate from the lighting circuit, to provide power items such as curling irons, razors, and hairdryers.

How many amps does a ceiling fan pull?





The majority of modern ceiling fans use less than an amp, averaging between 0.5 and 1 amp, depending on the model and the setting. One amp drawn by a ceiling fan is equivalent to about 120 watts. Low settings use less amperage while higher settings use more.

Can bathroom fan and light be on same circuit?

This is acceptable. Many bathroom fans include lights with the intention of both being wired to one switch on the same circuit. They can also be wired separately to different switches.

Can I wire a bathroom fan to the light switch?

Wiring a bathroom fan to a light switch is very straightforward. If the bathroom fan and light are separate fixtures, you’ll need a short wire to connect the two. Turn the power off, connect the white wires, connect the black wires, ensure it’s grounded, turn the power back on, and you’re good to go.

Can you wire outlets and lights on the same circuit for a bathroom?

No lighting outlets or other equipment can be fed from the same circuit feeding the bathroom receptacles. For example, a one-family dwelling has two bathrooms and a duplex receptacle has been installed in each. One 20-ampere branch circuit can supply power to both bathroom receptacles but cannot feed anything else.

What size wire do I need for a bathroom fan?



Wiring Considerations



Most bathroom ventilation fans use a 15-amp circuit breaker and 14-gauge wiring. Due to the increased power drawn, fans with heaters usually require a 20-amp circuit breaker and 12-gauge wiring.

How do you wire a bathroom fan with a light and heater?

Quote from the video:
Quote from Youtube video: The red is going to be the other white. The two blacks one of the blacks going to one of the blacks and one of the blues going the other one.

Do bathroom fans require GFCI?

Although the National Electrical Code (NEC) does not have a requirement for a bathroom exhaust fan to be GFCI protected, it is often specified by the manufacturer in the installation instructions when the fan is over a tub or shower.

What is code for bathroom exhaust fan?



Section R303.



When this section is adopted by a community, it essentially says that, for venting purposes, bathrooms must have windows that open. The code reads that the window must have “aggregate glazing area…of not less than 3 square feet (0.3 m2), one-half of which must be openable.”

How do you protect a GFCI bathroom fan?

Quote from the video:
Quote from Youtube video: We would have to install a gfci receptacle. Here as well as a gfci receptacle right there because the power comes into this. Box. Goes over to there. And up into the lights.

Can you put an exhaust fan directly over a shower?

You can place the fan directly over the bathtub or shower base, but it’s sufficient to position it anywhere near the bathing area. If the bathroom has both a tub and shower, or a shower and a whirlpool tub, the fan should go somewhere between the two fixtures.

Can a bathroom fan and light be in the shower?

Exhaust fans with a UL listing for installation over a tub or shower on a GFCI circuit can be installed over a tub or in a shower. This applies to most Air King exhaust fans and exhaust fans with light. Units that include any type of heating function to them are not able to be installed over a tub or shower.

Do bathroom exhaust fans need to be vented outside?



Bathroom fan installation requires outside ventilation. If the fan isn’t accessible through an attic, you’ll need to vent through a sidewall of your house. These types of ducts and vents are typically installed when the house is built.

Can 2 bathroom exhaust fans be vented together?

Well, you can’t! You’d often blow air from one bathroom into the other, and local building inspectors wouldn’t approve it. But while you can’t have two fans with one vent, you can make one fan and one vent serve two bathrooms.

Can you tie bathroom exhaust into plumbing vent?

The answer is no way! Sewer gas is explosive and could settle back into your exhaust fan which has an electric motor that is not rated for explosive gases.

How far can you run a bathroom exhaust vent?

Generally a 4 inch flex duct can carry a fan exhaust for up to 25 ft. Most codes require that.