To answer your question, no you cannot connect hot and neutral together ever. Sometimes the white wire is not used as a neutral, but used as a hot on a 240v circuit or a switch hot wire from a switch.

What happens if you cross hot and neutral?

If the hot wire comes into contact with both the neutral and the ground, then it will flow through both wires back to the source but as the ground has less resistance more current will flow through it.

What happens if you touch a hot and neutral wire together?





A short circuit happens when a “hot” wire (black) touches another hot wire or touches a “neutral” wire (white) in one of your outlets. When these two wires touch, a large amount of current flows, creating more heat than the circuit can handle, so it shuts off.

Can you put neutral and live wire together?

When a live wire and neutral wire come in direct contact, what happens? It is the condition of the short circuit if the live wire directly comes to the neutral wire. … If Normal wire burns, the circuit will break and everything will become normal except for that wire.

Should there be continuity between hot and neutral?

If you are testing from one of the phase wires on the load side of the main breaker with it off to the neutral you will get a reading if any of the branch circuit breakers are on and connected to loads. Turn off all of the breakers and check again it should read no continuity. It’s a new house.

Why would a hot and neutral wire be connected?

Quote from the video:
Quote from Youtube video: So the hot wires carry the electrical current from the supplier. And over to the load. And the neutral wires carry the electric current from the load.

Can I get a shock from neutral wire?





The neutral wire does have current going through it. However, we do not get shocked when we touch something with current going through it, we get shocked when current goes through us. In this case all of the current that enters one end of the section of wire we are touching also leaves the other end.

Why am I getting 120 volts on my neutral?

If you have a neutral wire removed from the neutral bus bar in your panel it is possible to see 120VAC on that wire if the circuit breaker for that circuit is turned on and there is a load connected to the circuit and load device is also turned on.

Can an open neutral cause a fire?

When there’s a loose wire connection, the neutral wire becomes abnormally hot and damages appliances in their wake. Most fires related to an electrical fault have an open neutral to blame.

What should voltage be between hot and neutral?

115 V to 125 V



So, what do you find? Hot-neutral is the load voltage. Voltage should read about 120 V (typically 115 V to 125 V).

Can neutral wire be hot?

If the neutral is disconnected anywhere between the light bulb and the panel, then the neutral from the light to the point of the break in the neutral will become hot (and the device will be unpowered, because no current will be flowing through it).

Can I tie red and black wires together?

These wires are typically used for switch wiring as well as the interconnection between smoke detectors hard-wired into the power system. You can link two red wires together, or you can link a red wire to a black wire. Since red wires conduct current, they are considered hot.

Can you tie neutral and ground together?



No, the neutral and ground should never be wired together. This is wrong, and potentially dangerous. When you plug in something in the outlet, the neutral will be live, as it closes the circuit. If the ground is wired to the neutral, the ground of the applicance will also be live.

What happens if ground wire touches hot wire?

A ground fault occurs in residential circuitry when a hot wire contacts the ground wire or a grounded element, such as a metal box, and electricity then flows immediately to ground. A tremendous amount of current flows during a ground fault—enough to cause electrocution and fires.

What happens if neutral wire touches ground?

In Short if neutral wire touches a earth wire,



An earth wire carrying load current is a risk of electric shock because a person touching this earth may present an alternative path for the load current and thus the risk of electric shock.

What is a floating neutral?

iTechworld portable generators are “floating neutral”, meaning that the neutral circuit is not connected to the frame or to earth ground. This also means that both legs on the receptacle are hot legs, which is normal for floating neutral generators.

Is it safe to have a floating neutral?



A Floating Neutral (Disconnected Neutral) fault condition is VERY UNSAFE because If appliance is not working and someone who does not know about the Neutral Floating could easily touch the Neutral wire to find out why appliances does not work when they are plugged into a circuit and get a bad shock.

What happens if neutral is not grounded?

Grounding neutral provides a common reference for all things plugged into the power system. That makes connections between devices safe(r). 2. Without a ground, static electricity will build up to the point where arcing will occur in the switchgear causing significant loss in transmitted power, overheating, fires etc.