Can you enclose a breaker box?

You are allowed to cover your electrical panel but it must be easy to open, can not interfere with the opening of the steel door of the panel and you have to make sure you have full access to all of the breakers. Keep in mind that some local electrical codes may prohibit the covering of your electrical panel.

How much clearance is needed around a breaker box?





A: According to NFPA 70-2011, article 110.26, a minimum of 36 inches clearance is required in front of all electrical equipment, including controls and panels, extending from the floor to a height of 6 foot 6 inches or the height of the equipment whichever is higher.

Can an electrical box be covered?

Junction box covers must remain accessible; they cannot be covered with drywall or other surface material. A junction box is most often used where an electrical circuit branches off in two or more directions from a location where an outlet or fixture is not practical.

How far does a panel have to be from a door?

“the working space around the breaker panel must be at least 30 inches wide and 3 feet of front clearance.” A door doesn’t count as an obstruction to the workspace requirement when closed.

What is the code for electrical panel clearance?

The National Electrical Code [NEC 110.26 (A)(1&2)] requires a clear area for access and working in front of an electric panel that is 2.5 feet (30”) wide, 3 feet (36”) deep, and 6.5 feet (78”) high for a regular residential 120/240-volt panel.

What is code for a breaker box?





Electrical Panel Placement Restrictions
The National Electrical Code 110.26 states that breaker boxes, and electrical equipment in general, must be placed in areas that provide sufficient working clearance around them. More specifically, the breaker box needs 3 feet of clearance in front of it.

How close can an electrical panel be to a wall?

For example, California’s state building code requires a minimum clearance of 30 inches horizontally in front of an electrical panel. This means you cannot place an electrical panel close to a corner if another wall, fixture or piece of furniture is within 30 inches of it.

Should electrical panels be covered?

Panels on the exterior of a home needs to have a cover. Damaged covers or panels without a cover may allow rain and snow to enter the panel and this could become dangerous, as well as a loss of power may occur.

How can I hide my electrical panel?

Strategically placed artwork, framed message boards, or a weaving or tapestry are all viable options for covering up obtrusive electrical eyesores. HGTV suggests inserting child proof safety plugs into unused outlets before covering with artwork.

Can an electrical panel be blocked?



Obstructed access to electrical panels and switches can prevent personnel from shutting down the source of power in the event of an accident. OSHA regulations and the National Electrical Code requires a clearance of at least 36 inches (3 feet)in front of electrical panels and electrical switches.

How much room do I need around an electrical panel?

The width of the working space must be at least 30 inches, or the width of the panel, whichever is greater. However, the panel is not required to be centered on the working space, it could be offset to one side or the other. But, the width of the working space must allow for the panel door to open at least 90 degrees.

Can electrical panel be in locked room?

Final Thoughts. According to OSHA, electrical door panels in commercial and industrial establishments should be closed and locked as a safety hazard. It should only be opened and accessed by trained personnel for repairs and other maintenance purposes.

Can a breaker panel be locked?



Locking your circuit breaker panel is one way to secure it. Furthermore, the most common way of locking a breaker box is by using a cabinet lock. It’s easy to install and only requires a few essential tools you likely have in your home.

Does OSHA require electrical panels to be locked?

The entrances to all buildings, rooms or enclosures containing exposed live parts or exposed conductors operating at over 600 volts, nominal, shall be kept locked or shall be under the observation of a qualified person at all times.

What is the most frequent violation of OSHA electrical standards?

According to OSHA’s top ten most cited safety violations in 2020, the most frequently cited electrical violation was the inability to control hazardous energy.

What is considered readily accessible?

(36) Readily accessible means capable of being reached quickly for operation, renewal, or inspection, without requiring those to whom ready access is requisite to climb over or remove obstacles or to resort to portable ladders, chairs, etc.