Can you wet vent a toilet drain?

Wet vents are typically used when plumbing a bathroom group. So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.

How far can you wet vent?

✔ The maximum run, which is the length from the drainpipe to the vent pipe, is 42-inch for a 1½ trap arm, 60-inch run for a 2-inch trap arm, and a 72-inch run for a 3-inch trap arm.

How far does the vent have to be from the trap?





Distance of fixture trap from vent.

Size of Fixture Drain, Inches Distance Trap to Vent
1-1/4 2 ft 6 in
1-1/2 3 ft 6 in
2 5 feet
3 6 feet

Where should the vent be on a toilet?

Quote from the video:
Quote from Youtube video: Right under the center of our plumbing wall the discharge side connects to the building drain further downstream.

What is the minimum size of a wet vent?

2 inches

The wet vent shall be sized based on the fixture unit discharge into the wet vent. The wet vent shall be not less than 2 inches (50 mm) in diameter for 4 drainage fixture units (dfu) or less, and not less than 3 inches (80 mm) in diameter for 5 dfu or more.

How tall does a toilet vent need to be?





The International Plumbing Code (IPC), requires plumbing vent pipes to extend vertically at least 152 mm (6 in.) above a roof, per Section 905.5, “Vent Connections and Grades.” Additionally, vent pipes must be at least 305 mm (12 in.) away from a vertical surface.

How far can a vent pipe run horizontal?

If you have 1- 1/4-inch pipe, the horizontal distance of the vent ought to not be more than 30 inches. For a 1- 1/2-inc pipe the vent must be 42 inches away at the most while a 2-inch pipeline must have an optimum distance of 5 feet.

Does toilet drain need vent?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.

Can a toilet and shower share the same drain?

The general answer is that the showers and toilets can use the same drain, but they should not be sharing the same waste trap arm. There are other factors to consider as well, such as whether your drains lead to the main sewer line, or if there are septic tanks that are used in your city or town.

How do you know if your toilet is vented properly?



Signs of Poorly-Vented Drain Lines

  1. Slow drainage — Slow drainage is probably the most common sign of poorly-vented drain lines. …
  2. Gurgling sounds — Drainage is usually not accompanied by noises, so any sounds coming from your drain lines could be a sign of poor ventilation.

Can a wet vent be horizontal?

There are different wet venting systems that both model and state plumbing codes allow. Vertical and horizontal wet vents are the most common of all these systems.

Can you put a 90 in a vent pipe?

Do not use the sharp, 90-degree vent elbow designed for venting above the water line. Note: You may have vent piping, but you still cannot use the tight 90-degree elbow — sometimes called a “vent elbow” — if the joint is below the water level, which is usually at the level of the sink. 3.

How many fixtures can be on a 2 inch vent?



The Plumbing Code states that a vent can handle 24 fixture units. A bathroom sink of 1.0 F.U., a bathtub of 2.0 F.U., and a shower of 2.0 F.U.

How far can a toilet be from a vent stack?

6 feet

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

Can 2 toilets share a vent?

Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack. Since the stacks must be vented, this would mean two vent openings on the roof.

Can two drains share a vent?



Common vent



This very simple concept allows two traps to be vented by the same vent. The two traps and their fixture drains can be either at the same level or at different levels, provided that they are on the same floor. The following diagrams show some of the various approaches to common venting.

Can you vent a toilet and sink together?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.

How do you vent a toilet drain?

Quote from the video:
Quote from Youtube video: Toilet vents are sized at a two inch. Minimum. So if that's you you can go with a three by three by two y with a two inch street 45 to vent your toilet i'll also quickly mention in upc. Jurisdictions.