The NEC only requires they be spaced 1-1/4 back or a nail plate is required, some quote 1” on center but reality is if there is a wood webbing between the holes it is an individual hole. Any holes not directly above the panel require holes in the studs.

How close can holes be in top plate?

2 inches





Holes shall not be closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the notch.

Can you drill through a load bearing top plate?

When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 percent of its width, a galvanized metal tie not less than 0.054 inch thick (1.37 mm) (16 ga) and 11/2 inches (38 mm) wide shall be fastened …

Where do you drill holes in wood beams?

You should also avoid drilling within 1′ of where a beam sits on top of a support column or post. 2. On overhead spans, the 1/3 1/3 rule generally applies. Only drill within the 1/3 middle of the span horizontally and the 1/3 middle vertically.

How many holes can be drilled in a stud?

Holes in bearing wall studs (exterior and interior walls that bear the weight of the roof and/or other stories above) may not exceed 40 percent of the width of the stud. Notches in bearing wall studs may not exceed 25 percent of the stud’s width. Holes in non-bearing walls can’t exceed 60 percent of their width.

Can you drill through load-bearing wall?





The general rule for cutting holes in a load bearing wall is that the diameter of the hole cannot exceed 1/3 the width of the stud.

What are spade bits?

A spade bit is a wood-boring drill bit that is flat with two sharp lips. The spade bit was invented by the Irwins tool company in 1968 and its design allows for it to scoop material out of a bore-hole quickly.

How many wires can be in a stud hole?

The Answer. According to the National Electrical Code, you can have 4 12/2 nonmetallic sheathed cables through a single bored hole that is fire- or draft-stopped using thermal insulation, caulk, or sealing foam, or where proper spacing is not maintained for more that 24 in.

Can I reuse a stud hole?

Assuming that the screws don’t feel loose when you remove them due to inadequate length or pilot holes that are too large, you can reuse the holes.

How big should the hole be for Romex?



Large Holes

The larger the hole for the ROMEX® wire the better off you are, as long as you don’t compromise the structural integrity of the 2-by-4. If you go by the 1/3 rule, then 1 1/8 diameter is the maximum diameter, but that only gives the wire 1 1/8-inch protection from nails and wall board screws.

How many wires can be in a 3/4 hole?

arichard21. my inspector told me that they must not take up more than 50% of the capacity of the hole, or 4 wires max through ANY size hole. he said 3 12-2 wires is pushing it for 3/4″, but is still okay.

How high do you run electrical wire?



We usually run them close to the height that the receptacles are to save wire many of the homes I have wired run from 8” to 24” with most 12-16” I like the taller ones because boring the holes through the studs is easier a little higher, just make you bore your hole in the center of the board so there is 1-1/4” or more …

How thick is Romex wire?

The cable jacket is color-coded for quick size identification; White – 14 AWG, Yellow – 12 AWG, Orange – 10 AWG, and Black – 8 AWG and 6 AWG. Insulation Thickness (mils) Ground Wire Approx. + Ampacities per National Electrical Code section 310.15 and 334.80. NOTE: Jacket thickness for all NM-B cable is 30 mils.

How far can you run 12 gauge wire on a 20 amp circuit?

After these distances, the circuit will go over the recommended 3% voltage drop. You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

Can I use 12 gauge wire on a 15 amp circuit?

Because it has even less chance of overheating, 12-gauge wire is also acceptable on a 15-amp circuit.