Yes you can, but the proper thing to do would be to run a whole new cable from the panel to that first box. If you can do it with a ground wire it is not much harder or more expensive to do it right with a new cable.

Can I connect a ground wire to another ground wire?

Quote from the video:
Quote from Youtube video: The ground wire from the green terminal on the receptacle. The one that's connected to the metal box.

Can you add a ground wire to old wiring?





It’s perfectly legal to run JUST a ground wire to retrofit old work. You do not need to also pull all the conductors.

What can I use to extend a ground wire?

Quote from the video:
Quote from Youtube video: We're going to splice in some jumper wires and use these pushin style connectors. You can find them at any Home Center store cut off the old loops and strip off a half an inch of insulation.

What do you do if the ground wire has no ground?

What to do When there is Nothing to Attach the Ground Wire

  1. When you have a ground wire and there is no place to attach it then place a wire connector over the end, coil up the ground wire and push it back into the electrical junction box.
  2. IMPORTANT: Never cut the ground wire off.

How do I ground an old electrical outlet?

Quote from the video:
Quote from Youtube video: The white pigtail will tied to the neutral bar and the ground we've just installed will tied to the grounding bar. All right we're just gonna plug this last machine.

How do you connect ground wires together?





Quote from the video:
Quote from Youtube video: So what I'm going to do is take these I can overlap them okay just put a loop in it like that. Get it back there as far as you can now I'm going to take my pliers. And give it a couple little twists.

Can you install 3 prong outlet without ground?

However, most newer appliances require an outlet that has three prongs for it to be plugged in. This has led many homeowners to incorrectly install a three prong outlet without properly attaching a ground wire. This can lead to many problems including risk of shock and appliances suffering from power surges.

How do you twist two ground wires together?

Twist a wire nut firmly onto the end of the twisted ground wires. Put a curl in the end of the pigtailed piece of ground wire. Hook the curl around the green ground screw with the open side of the curl on the right. Tighten the ground screw securely with your straight screwdriver.

Can you connect ground wire to white wire?

No, the neutral and ground should never be wired together. This is wrong, and potentially dangerous. When you plug in something in the outlet, the neutral will be live, as it closes the circuit. If the ground is wired to the neutral, the ground of the applicance will also be live.

Can 2 ground wires touch?



The reason that wiring devices have grounding connections that accept only one wire is that otherwise, if two ground wires were connected to the device, then if someone later removed that wiring device and then re-applied power without wire-nutting the grounding conductors, there would be a break in the ground path for …

How do you make a ground loop?

A ground loop is formed when there is more than one conductive path between the “ground” terminals on two or more pieces of equipment. The conductive loop forms a large loop antenna that picks up interference currents easily.

Can ground and neutral be on the same bar?

The answer is never. Grounds and neutrals should only be connected at the last point of disconnect. This would be at main panels only.

Where do you bond ground and neutral?



Neutral wires are usually connected at a neutral bus within panelboards or switchboards, and are “bonded” to earth ground at either the electrical service entrance, or at transformers within the system.

Why do neutral and ground need to be separated?

With ground and neutral bonded, current can travel on both ground and neutral back to the main panel. If the load becomes unbalanced and ground and neutral are bonded, the current will flow through anything bonded to the sub-panel (enclosure, ground wire, piping, etc.) and back to the main panel. Obvious shock hazard!

Can you touch neutral bar in panel?

You can touch a neutral bus bar assuming the circuit is correctly grounded. The reason this is possible comes down to the amount of voltage in a current. The current passing through to a neutral bus bar will already have been used by the load.

Can you get a shock off a neutral bar?

So even the current returns through neutral (only from a connected load that completes the current flow circuit) you touching the neutral with a 0V cant get you a shock. But its not safe to touch neutral wire!

What is the difference between a neutral bar and a ground bar?



Neutral bars have a heavy, high-current path between the bar and neutral lug, which is itself isolated from the chassis It is obvious that the neutral lug-to-bar connection is heavy, and designed to flow a lot of current all the time. Ground bars are, by design, in direct contact with the panel chassis.