According to plumbing code, here, drain pipes must be sloped a minimum of 1/4-inch per foot and a maximum of three inches per foot, or they must be vertical. A slope of less than 1/4-inch per foot will cause constant drain clogs and a slope of more than three inches will allow the water to drain without the solids.

Do drain pipes need to be angled?

All drain lines should have a minimum fall of 1/8 inch per foot of horizontal run. Some codes allow a quarter inch of fall per foot. If you slope the pipe much more than a quarter inch per foot, you can set yourself up for future clogs, as liquids may outrun the solids in steep-pitched pipes.

What is the required slope for drainage?





For efficient drainage, paved surfaces should have a minimum 1-percent slope. Turf or landscaped areas should have a minimum slope of 2 percent.

Can a drain pipe be level?

Quote from the video:
Quote from Youtube video: And it takes a little bit back and forth there you go. So now I'm between the lines on that green one that now represents a half inch per foot. So when I go put this level on any pipe.

Can a drainage pipe go uphill?

Quote from the video:
Quote from Youtube video: Okay.

Does a sewer line have to be straight?

You should design your wastewater pipes in a similar manner, for the most part. It’s a bad plumbing practice to have a hard 90-degree bend in a horizontal drain line that’s buried in a slab or otherwise hidden.

What fall should a waste pipe have?





1 in 40

What is the recommended fall for a soil pipe? The minimum fall for a waste pipe is 1 in 40. The maximum fall is 1 in 110 (apart from vertical pipes but that’s a different story). So pipes with a gradient between 1 in 40 and 1 in 110 should have adequate flow to prevent blockages from occurring.

What is the minimum slope of horizontal drainage pipe?

Horizontal drainage piping shall be installed in uniform alignment at uniform slopes. The minimum slope of a horizontal drainage pipe shall be in accordance with Table 704.1. For SI: 1 inch = 25.4 mm, 1 inch per foot = 0.083.

What is the minimum slope or pitch of horizontal drainage pipe?

1/4 inch per foot



The slope of a horizontal drainage pipe shall be not less than that indicated in Table 704.1 except that where the drainage piping is upstream of a grease interceptor, the slope of the piping shall be not less than 1/4 inch per foot (2-percent slope).

What is the minimum slope of a 2 inch drain line?

Minimum Pipe Slope



As a general rule, the recommended slope for most plumbing pipes is 1/4 inch vertical drop over every 1 horizontal foot, or about 2 percent, reveals Builder’s Calculator.

How do you slope a PVC drain pipe?

Quote from the video:
Quote from Youtube video: And I taped it on to the end of the level with just electrical tape I put my level on the pipe like this keep that on the downhill. Side. Then it shows right on level. When I get my slope right that.

How much slope does a PVC drain pipe need?



¼ inch per foot

But do you know the proper slope? The ideal slope of any drain line is ¼ inch per foot of pipe. In other words, for every foot the pipe travels horizontally, it should be dropping ¼ inch vertically.