Can you have 2 electrical panels?

If you are in the US, then the answer is yes. The main electrical drop has to be sized for both panels and each panel should have its own utility meter. All NEC codes must be conformed to. You need to consult your local government to see about local codes as well.

How do you run a 200 amp service?





Quote from the video:
Quote from Youtube video: Nice job now this is your new meter socket it's rated for 200 amps the power comes in through the top ties onto these two terminals. Goes through the meter comes out on the bottom two terminals.

How do you wire a 200 amp meter box?

Quote from the video:
Quote from Youtube video: And just get the casing. Around the scu cable. Cut. All right so now we need to separate. The red and the black. Over here this one we can put there.

How many circuits can you put on a 200 amp panel?

How many circuit breakers in a 200 amp panel? Most 200-amp breaker panels have 40 to 42 slots of single-pole breakers or 20 slots for double pole breakers. And although a 200 amp panel has many places for circuit breakers, that does not mean you can use all of it.

How many subpanels can you have on a 200 amp service?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

What size wire do I need to run 200 amp Service 200 feet?





Installation of 200 amp electrical service needs a #2/0 AWG copper wire or #4/0 AWG for aluminum or copper-clad wire inside a minimum of 1.5 inches, schedule 40 or 80 PVC conduit for underground service. However, 2 or 2.5 inches is recommended if running 3 wires in the same conduit.

What size wire do I use for a 200 amp service?

For a 200 amp service, you’ll need: #2/0 copper wire, or. #4/0 aluminum or copper-clad aluminum wire.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How many kilowatts can a 200 amp panel handle?

In this case, it will be either 120 volts x 200 amps = 24,000 watts or 240 volts x 200 amps = 48,000 watts.

How many 100 amp breakers can you have on a 200 amp panel?



Nothing inherently wrong with 2 100A breakers in one box plus lots of other breakers – i.e., oversubscribing the 200A total is perfectly fine if real-world usage will stay under 200A.

Can I put a 100 amp main breaker in a 200 amp panel?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance,

Can subpanel be bigger than main panel?

if the subpanel’s main breaker is larger than the supply breaker, it has no effect. if smaller than the supply breaker, the subpanel’s main breaker protects the subpanel.

How far can subpanel be from main panel?



The right feet would be between 4.5 to 5 feet.



The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

Can a subpanel feed another sub panel?

Answer: Yes. The main electrical service panel is where branch circuits originate. A branch circuit consists of the circuit conductors between the final over-current device protecting the circuit and the lights, receptacles and equipment supplied by the branch circuit.

Can you run a 100 amp sub panel off a 100 amp main panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.

What is the difference between a main panel and a sub panel?

The main panel is directly connected to the point of entrance to a building, and all sub-panels feed off that connection. However, the sub-panel provides a useful methodology for installing outlets that help you organize your electrical system into something more manageable.

How many wires can be in a subpanel?



A subpanel requires two hot wires connected to a 240-volt double-pole breaker in the main panel. It also needs a neutral wire and a ground wire. The cable used for this run is known as a “three-wire cable with ground.” The two hot wires, called feeder wires, will provide all of the power to the subpanel.

Can I use a main panel as a sub panel?

There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.