Can you put a 50 amp breaker in a 60 amp panel?

The 50A breaker will be protecting the wiring to the tub (and internals of the tub). The 60A breaker is protecting the wiring to the subpanel (and its internals). You can do this if you want and you will be perfectly fine.

Can I add a 50 amp breaker to my sub panel?





So in short a 50 amp breaker can be used in a 70 amp panel but if your breaker feeding the panel or the wiring is not sufficient size it won’t work. Yes, as long as the breaker protecting the panel is sized for the panel then you can put anything up to the same size in the sub-panel.

Can I put a 50 amp breaker in a 50 amp sub panel?

Assuming you’ve got 6 gauge wire feeding the sub panel, you should be fine. As long as you aren’t pulling more than 50 amps through that sub panel at once, you don’t need to worry about over loading the panel. That’s what the 50 amp breaker is there for.

How many breakers can I put in a 60 amp subpanel?

Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

How many amps can a 50 amp breaker handle?

A 50 Amp split phase 120/240 VAC service should be capable of 50 Amps per leg for a total ampacity of 100 Amps. It’s true that you have 50 Amp on each leg for 100 Amp total, but if you get up to 45 Amp continuous on one leg, you will trip the breaker.

What size wire do I need to run a 60 amp subpanel?





In short, the wire size for a 60 amp sub-panel 150 feet away is 3 AWG gauge wire.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Can you put a 50 amp breaker in a 100 amp panel?

The number of breakers can max out to 30-42, too, depending on the design of your 100-amp pane. However, NEC prohibits more than 42 circuits, so you can only choose between 20-42 breakers for a 100-amp panel. Breakers or circuit breakers act as a switch for cutting off power from the main electrical supply.

What gauge wire do I need for a 50 amp sub panel?

6 AWG Wire



6 AWG Wire Used For 50 Amp Service.

How many amps does it take to trip a 60 amp breaker?

If it’s located on the higher side of the panel, expect a reduction of at least 5 amps in its total capacity. Don’t forget how long the electrical load lasts. The longer the load lasts, the sooner the breaker trips. Take note that it only takes 3 minutes of continuous 60-amp load to trip a 60-amp breaker.

How many watts can a 60 amp sub panel handle?

The amount of power that each circuit can handle is the number of volts (usually 120) times the number of amps. Therefore, that 60 amp circuit can handle 7200 watts.

How many appliances can be on a 60 amp circuit?



Electrical Load Box Sizes
A small, 60-amp fuse box might be found in an older home that has not had its wiring upgraded. It can supply power to only one 240-volt appliance, such as an oven or a clothes dryer.

What size wire do I need to run 50 amps 100 feet?

6 AWG

For every 100 feet, voltage drops by 20%.
Example: 50 amp wire is usually the 6 AWG (we require at least 62.5A and 6 AWG can handle 65A). If you have to power an electric device 100 feet away, you need 20% amps more. Instead of 62.5A, you’re looking at 62.5A × 1.2 = 75A.

What is a 60 amp breaker used for?

The Square D by Schneider Electric Homeline 60 Amp Two-Pole Circuit Breaker is used for overload and short-circuit protection. Homeline load centers are compatible with this breaker.

Can I use a 50 amp breaker for a 40 amp stove?



Using a 50A plug and receptacle is allowed on a 40A circuit because of an exception in the Electrical Code. The exception is because 40A receptacles do not exist, or rather, are not part of the NEMA standards.

Does a range need a 50 amp breaker?

What Breaker Size Do I Need for an Electric Stove. The industry standard for an electric stove is a 50 amp double-pole circuit breaker.

What size breaker is needed for an electric range?

The vast majority of modern electric stoves require a 50 amp breaker. Smaller or older stoves often draw less power and use 30 or 40 amp circuit breakers. Larger industrial electric stoves often need a larger circuit breaker at 60 amps or more.

What would you use a 50 amp breaker for?

A 50-amp breaker can run appliances like ovens, hairdryers, air conditioners, and multiple lights simultaneously while (possibly) still sparing power. The reason for this breaker’s capacity is because it can hold up to 12,000 watts running on a 240-volt circuit (50-amps x 240-volts).

Is a double 30 amp breaker the same as a 60 amp breaker?



A main breaker is the same as any double breaker in the box, except that it supplies power to each busbar. The answer is no if you want to draw 60 Amps off a 30 Amp double breaker.

Can you use #8 wire with a 50 amp breaker?

Can 8-Gauge Wire Handle 50 Amps? A copper conductor’s conductivity is affected by temperature. Up to a point, the higher the temperature, the higher the current the wire can handle. An 8-gauge wire can handle a current of 50 amps at a temperature of 90-Celsius or 194-Fahrenheit.