Can you have 2 electrical panels?

If you are in the US, then the answer is yes. The main electrical drop has to be sized for both panels and each panel should have its own utility meter. All NEC codes must be conformed to. You need to consult your local government to see about local codes as well.

Can you have 2 main breakers?





A main service panel can have up to six main breakers, per National Electrical Code [230.72(A)]. Almost all modern panels have a single main breaker, which is called a “service disconnect” in the electrical code, but more are allowed.

Why do I have 2 electrical panels?

However, did you know that a house may have more than one breaker panel installed? The secondary breaker box is called a sub-panel and serves to split the load for the building to cover multiple areas. It can also be used to isolate one part of the building from another electrically.

Can I have 2 100 amp panels?

You probably can, but you will still only have 100 amps to use. More panels do not give you more power, only your power provider can do that,after upgrading service/panel/s.

Can I have 2 subpanels?

You can add as many subpanels as you need providing the combined electrical demand is below 160 amps. If all the circuitry was operating at once, the electrical service could become overloaded. However, all combined circuitry would not likely be on at any given time.

Can you run a 100 amp sub panel off a 100 amp main panel?





Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.

Are tandem breakers legal?

Tandem breakers are safe and legal to use only when the panel is designed for them and only in the slots that accept tandem breakers.

How many circuits can be on a 100 amp panel?

Typical 100-amp panels have 20 circuits, meaning they can handle 20 full-sized breakers. 20/24 panels can hold 16 full-sized and 4 twin breakers (24 circuits in total). The number of breakers can max out to 30-42, too, depending on the design of your 100-amp pane.

How much load can a 100 amp panel handle?

In other words, a 100-amp electrical service should be expected to provide no more than 19,200 watts of power load at any given time.

Can I run a 200 amp sub panel off 200 amp main?



Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can I feed a 200 amp sub panel with a 100 amp breaker?

Yes. There is no real NEC provision that would prohibit this so it’s allowed. The 200 amp CB is simply being used as a disconnect if the feeder is protected by a 100 amp OCPD at it’s origin.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Can you daisy chain subpanels?



Answer: Yes. The main electrical service panel is where branch circuits originate. A branch circuit consists of the circuit conductors between the final over-current device protecting the circuit and the lights, receptacles and equipment supplied by the branch circuit.

Can I run a subpanel from another subpanel?

Can I run a subpanel from a subpanel? Generally speaking, yes. You could put a million subpanels in series, and by itself that wouldn’t be a code violation. The metal conduit can act as the equipment ground so a 4th wire is not required.

How many 220v outlets can you have on a 200 amp service?

Most 200-amp breaker panels have 40 to 42 slots of single-pole breakers or 20 slots for double pole breakers.

How many circuits can be on a 200 amp breaker?

The number of circuits and breakers you can install in an electrical panel is limited by the panel’s design. Most 200 amp panels will have 40 breaker slots but can accept more circuits with tandem breakers. 120v single-pole breakers will use 1 breaker slot, while 240v double-pole breakers will use 2 breaker slots.

Can you use a 200 amp meter socket for 100 amp service?



This is legal and it makes the service 100 amp not 200, however the wire will not fit under a 100 amp breaker. You will need to bug on a short piece of wire that would be the appropriate size for 100 amp.

How many tandem breakers are allowed in a 200 amp panel?

A 150-amp panel would allow a maximum of 30 circuit poles, and a 200-amp panel would allow a maximum of 40 circuit poles. For panelboards not manufactured as “lighting & appliance” panelboards, there is no limit to the number of circuit breakers allowed.

Are tandem breakers a code violation?

No, it’s not. The use of tandem circuit breakers is a perfectly acceptable practice, as long as the panelboard is designed for tandem circuit breakers and they’re installed in locations within the panelboard where they’re allowed.

What is a piggyback breaker?

In the space of one 1″ breaker, fits two breakers side-by-side (Twin) or over/under (Piggyback).