What would cause a furnace blower not to kick on?

If you see or hear the fan turn on, your blower motor is not the culprit. If the fan does not start, you have a wiring issue (circuit breaker trips) or motor problem (circuit breaker does not trip). While your thermostat may be at fault, only an HVAC technician can diagnose and remedy the issue correctly.

How do you know if your HVAC blower motor is bad?





What Are Signs Your Blower Motor Needs to Be Replaced?

  1. Poor or Airflow from Air Vents. This will be the first and most obvious sign your blower motor has a problem. …
  2. No Airflow At All From Vents. …
  3. Skyrocketing Energy Bills. …
  4. Strange Noises When You Turn on the Heat. …
  5. Overheating Blower / Weird Smells.


Why will a blower run on the on position and not on auto?

That’s because if the heater never warms up then the fan controller won’t automagically turn on the blower fan. Let me know what you find. Electric split unit trane the fan comes on in the on position but not in automatic. Heat or cool isn’t working on the condenser or evaporator .

Why is my furnace blower constantly running?

If your fan limit switch is set to AUTO but the fan continues to run without ever stopping, you’ll need to call a professional. Two problems that could cause your fan to run without stopping include: A bad fan limit switch that needs to be replaced. Bad thermostat wiring.

Why does my blower motor work sometimes?





When a blower resistor fails, the highest fan speed usually is the only one that still works because it essentially bypasses the resistor and receives the maximum amount of voltage. When the resistor is working, it reduces the amount of voltage going to the lower fan speeds so the fan runs slower.

How do you reset furnace blower?

Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.

How much does it cost to replace blower motor in HVAC?

Replacing a blower motor costs $450 on average with a typical range of $250 to $800. With a warranty, you might pay as little as $150 for labor alone. For high-end models, like those with large motors or access issues, you might pay as much as $2,000.

How much should it cost to replace a furnace blower motor?

A blower motor replacement costs $300 to $900 on average if not under warranty or $200 to $400 for labor when under warranty. Replacing a large or variable-speed HVAC blower motor costs $600 to $1,500. Furnace or AC blower motor prices are $100 to $500 on average for the part alone.

What happens when blower motor relay goes bad?



If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.

How do I test my HVAC blower motor relay?

Quote from the video:
Quote from Youtube video: Set your meter to the lowest resistance level. And you should read approximately 70 80 ohms of resistance. We're showing 79 it's good now between the other side five and six should show closed two.

How can you tell if a blower fuse is bad?

If you hear that the blower motor is operating but don’t feel any air flowing through the vents, the problem is with the airflow controls [source: RepairPal]. If the blower motor isn’t running you should: Use voltmeter or ohmmeter to check for a blown fuse.